HALCON 7.1 Frame Grabber Interface for Silicon Software microEnable III Boards
This page provides the documentation of the HALCON mEnable3
interface for the microEnable III frame grabber boards from
Silicon Software GmbH.
Registered
customers can download the
latest
revision of this interface from the
MVTec WWW server.
Revision: 2.3
System Requirements
-
Intel compatible PC with Windows 2000/XP.
-
Successfully installed Silicon Software driver (version 3.1).
Make sure that the environment variable %SISODIR% is set
correctly to the directory that contains the Dlls for the desired
hardware applet, e.g.,
C:\Program Files\Silicon Software\dll\me_grab3.
-
HALCON frame grabber interface HFGmEnable3.dll or
parHFGmEnable3.dll, respectively.
If you have properly installed the interface, both DLLs should
reside in bin\i586-nt4 within the HALCON base directory
%HALCONROOT% you have chosen during the installation of HALCON.
Features
-
Support of a variety of CameraLink cameras based on the
Silicon Software hardware applets.
-
Multiple frame grabber boards.
-
Synchronous and asynchronous grabbing.
-
External and software trigger.
-
Cropping of image parts.
-
Software control of the digital input and output lines.
-
Support of shaft encoders (microEnable III-XXL only).
Limitations
-
Currently only the 'Single' hardware applets are supported.
-
grab_region and grab_region_async not supported.
-
No LUTs.
Description
Parameters for
open_framegrabber():
|
Name
|
'mEnable3'
|
The name of the HALCON frame grabber interface.
|
|
HorizontalResolution
|
1
|
Ignored (the desired image resolution is set via the camera
configuration file specified in the CameraType parameter!).
Default: 1.
|
|
VerticalResolution
|
1
|
Ignored (the desired image resolution is set via the camera
configuration file specified in the CameraType parameter!).
Default: 1.
|
|
ImageWidth
|
0, width
|
The width of the desired image part ('0' stands for the maximum
image height). This value has to be equal or smaller than the
maximum image height. If the value does not fit in the step width,
it is rounded to next valid value. Default: 0.
|
|
ImageHeight
|
0, height
|
The height of the desired image part ('0' stands for the maximum
image height). This value has to be equal or smaller than the
maximum image height. If the value does not fit in the step width,
it is rounded to next valid value. Default: 0.
|
|
StartRow
|
row
|
The row coordinate of the upper left pixel of the desired image part.
If the value does not fit in the step width,
it is rounded to next valid value. Default: 0.
|
|
StartColumn
|
column
|
The column coordinate of the upper left pixel of the desired
image part. If the value does not fit in the step width,
it is rounded to next valid value. Default: 0.
|
|
Field
|
---
|
Ignored.
|
|
BitsPerChannel
|
---
|
Ignored (the desired pixel depth will be set accordingly to the
parameter settings in the camera configuration file).
|
|
ColorSpace
|
---
|
Ignored (the desired color space will be set accordingly to the
parameter settings in the camera configuration file).
|
|
Gain
|
---
|
Ignored.
|
|
ExternalTrigger
|
'true', 'false'
|
If set to 'true', the trigger mode will be set to
'async_trigger', otherwise 'free_run' mode will be active.
Default: 'false'.
|
|
CameraType
|
'mcf file'
|
Specify the name (including the full path name) of the desired
camera configuration file (mcf file). To configure a specific
camera setup please use the microDisplay program which
is part of microEnable III software.
|
|
Device
|
'0', '1', ...
|
The number of the frame grabber board (passed as a string!).
Default: '0'.
|
|
Port
|
0, 1
|
Specify the port the camera is connected to.
Default: 0.
|
|
LineIn
|
---
|
Ignored.
|
|
Parameters for
set_framegrabber_param():
|
'continuous_grabbing'
|
|
'enable', 'disable'
|
|
Activate or deactivate the continuous grabbing mode.
If the continuous mode is enabled, the frame grabber board will
grab all the time. Note that in this mode you can acquire images
from line scan cameras without loosing any image data.
This mode is not allowed in combination with external
triggering. Default: 'disable'.
|
|
'digital_output'
|
0, 1, 2, 3
|
Specify the combination of the two digital output signals.
|
|
'exposure'
|
0 ... 1000000
|
Exposure time in µs. Default: 4000.
|
|
'exposure_signal'
|
'high_active', 'low_active'
|
Polarity of the exposure signal. Default: 'low_active'.
|
|
'flash_signal'
|
'high_active', 'low_active'
|
Polarity of the flash signal. Default: 'low_active'.
|
|
'frame_rate'
|
0.5 ... 20000.0
|
Number of images per second.
|
|
'grab_timeout'
|
msec
|
Specify the desired timeout (milliseconds passed as an integer) for
aborting a pending grab. Default: 5000.
|
|
'image_height'
|
height
|
The height of the desired image part. Note that due to image
buffer re-allocation this setting may take some time.
|
|
'image_trigger'
|
'enable', 'disable'
|
Enable or disable the image trigger.
|
|
'image_trigger_input'
|
0, 1, 2, 3
|
The input source, if the image trigger is in external mode.
|
|
'image_trigger_mode'
|
'free_run', 'async_trigger', 'async_gated'
|
The image trigger for line scan cameras generates an socalled
Image Gate, which groups all lines to a valid frame, if it is
active. Specify the desired image trigger mode: 'free run'
means, that the Image Gate is valid all the time. In 'async_trigger'
mode the Image Gate is started by an external trigger signal.
'async_gated' means that the Image Gate is as long active as the
external trigger source is active.
In all modes the Image Gate becomes inactive after reaching an
image height of N lines.
|
|
'image_trigger_signal'
|
'falling', 'rising'
|
The input signal of the image trigger, in case external mode.
|
|
'image_width'
|
width
|
The width of the desired image part. Note that due to image
buffer re-allocation this setting may take some time.
|
|
'line_downscale'
|
1 ... 255
|
If your external trigger signal is too fast, you can set the value
of how often the frequency of the trigger signal has to be divided.
|
|
'line_downscale_phase'
|
1 ... 255
|
In additional to the downscale value you can set the phase position.
For example, a value of 4 means to turn the phase position about 90°.
|
|
'line_exposure'
|
0 ... 20000
|
The line exposure.
|
|
'line_period'
|
0 ... 4369.05
|
The line period.
|
|
'line_trigger_delay'
|
0 ... 2184.517
|
The delay of the line trigger.
|
|
'line_trigger_input'
|
0, 1, 2, 3
|
The input source of the line trigger.
|
|
'line_trigger_mode'
|
'grabber_controlled', 'async_trigger', 'grabber_controlled_gated'
|
Specify the line trigger mode: 'grabber_controlled' means that
a periodical signal is created, which defines the line frequency.
In 'async_trigger' mode the signal is created by an external trigger.
'grabber_controlled_gated' is similar to the 'grabber_controlled'
mode, except that it is only active, if the Image Gate is active.
|
|
'line_trigger_signal'
|
'falling', 'rising'
|
The polarity of the line trigger signal.
|
|
'port'
|
0, 1
|
Switch to the camera with the specified number (0 for Port A,
1 for Port B).
|
|
'shaft_encoder'
|
'enable', 'disable'
|
Switch the shaft encoder on/off. By enabling it the encoder
compensation is reset. This parameter is only available for
microEnable III-XXL boards.
|
|
'shaft_encoder_input'
|
0, 1, 2, 3
|
Selects the input signal for source B of the shaft encoder.
This parameter is only available for
microEnable III-XXL boards.
|
|
'shaft_encoder_leading_source'
|
0, 1, 2, 3
|
Determines the leading signal (direction) of the shaft encoder
filter. This parameter is only available for
microEnable III-XXL boards.
|
|
'start_async_after_grab_async'
|
'enable', 'disable'
|
By default, at the end of grab_image_async a new
asynchronous grab command is automatically given to the frame
grabber board. If the parameter 'start_async_after_grab_async' is
set to 'disable' this new grab command is omitted. This might be
useful especially for switching between several connected cameras.
Default: 'enable'.
|
|
'start_column'
|
column
|
The column coordinate of the upper left pixel of the desired
image part.
|
|
'start_row'
|
row
|
The row coordinate of the upper left pixel of the desired
image part.
|
|
'strobe_delay'
|
usec
|
Strobe pulse delay in µs. Default: 0.
|
|
'trigger_input'
|
0, 1, 2, 3
|
Specify the desired channel of the trigger input signal.
|
|
'trigger_mode'
|
'free_run', 'grabber_controlled', 'async_trigger',
'async_software_trigger'
|
Specify the desired trigger mode: 'free_run' means that no signals
are sent to the camera. In 'grabber_controlled' mode the frame
grabber sends a signal to the camera in order to control the image
acquisition. In 'async_trigger' mode the image acquisition is
forced by an external trigger signal, and 'async_software_trigger'
means that the image acquisition is performed by software via
the action parameter 'do_force_trigger'.
|
|
'trigger_signal'
|
'falling', 'rising'
|
Polarity of the trigger signal. Default: 'falling'.
|
|
'volatile'
|
'enable', 'disable'
|
Grayscale only.
In the volatile mode the frame grabber interface buffers are
used directly to store HALCON images. This is the fastest mode
avoiding to copy raw images in memory. However, be aware that older
images are overwritten again and again as a side-effect. Thus, you
can only process one image while you grab another image. Older
images are invalid! Default: 'disable'.
|
|
'do_abort_grab'
|
---
|
Cancel current grab.
|
|
'do_exsync'
|
'enable', 'disable'
|
Switch on/off the exsync signal to the camera.
|
|
'do_flash'
|
'enable', 'disable'
|
Switch on/off the flash signal to the camera.
|
|
'do_force_trigger'
|
---
|
Send a software trigger from the application to the camera.
This action parameter is only applicable when the trigger mode
is set to 'async_software_trigger'.
|
|
Parameters for
get_framegrabber_param():
Additional parameters supported by get_framegrabber_param only.
Note that all parameters supported by set_framegrabber_param
except the ones with prefix 'do_'
can also be accessed by get_framegrabber_param.
|
'board_type'
|
|
'mEnable3', 'mEnable3_XXL'
|
|
Returns the actual board type.
|
|
'camera_status'
|
status (long)
|
Return camera status on the used port: If the return value is 1
an active camera on the specified port is found, otherwise
the return value is 0.
|
|
'digital_input'
|
digin (long)
|
Read the current status of the digital input lines.
|
|
'revision'
|
revision (string)
|
The revision number of the HALCON mEnable3 interface.
|
|
Release Notes
-
Revision 2.3 (Jan 29, 2008):
-
Fixed bug in info_framegrabber('info_boards') to
ensure the correct information about actually installed devices
also in case of multiple boards of the same type.
-
Revision 2.2 (Oct 18, 2006):
-
Added parameter 'board_type'.
-
Fixed bug in info_framegrabber.
-
Revision 2.1 (Jul 28, 2006):
-
Adapted to SDK version 3.1.
-
Added parameters for line scan cameras and shaft encoders:
'image_trigger', 'image_trigger_input', 'image_trigger_mode',
'image_trigger_signal',
'line_downscale', 'line_downscale_phase', 'line_exposure',
'line_period', 'line_trigger_delay', 'line_trigger_input',
'line_trigger_mode', 'line_trigger_signal', 'shaftencoder',
'shaftencoder_input', 'shaftencoder_leading_source'.
-
Fixed bug in 'do_abort_grab' and in 'do_flash'.
-
Added 'info_boards' in info_framegrabber.
-
Revision 2.0 (May 31, 2005):
-
HALCON 7.1 version of the interface (included in HALCON 7.1 CD).
-
First official release.
|