MVTec Software GmbH
  Building Vision For Business
Halcon

HALCON 8.0 Image Acquisition Interface for Silicon Software microEnable IV Boards

This page provides the documentation of the HALCON mEnableIV interface for the microEnable IV frame grabber boards from Silicon Software GmbH. Registered customers can download the latest revision of this interface from the MVTec WWW server.

Revision: 3.2

System Requirements

  • Intel compatible PC with Windows 2000/XP.
  • Successfully installed Silicon Software driver (version 3.3 or higher). Make sure the environment variable %SISODIRME4% is set correctly to the SiliconSoftware base directory.
  • HALCON image acquisition interface hAcqmEnableIV.dll or parhAcqmEnableIV.dll, respectively. If you have properly installed the interface, both DLLs should reside in bin\%HALCONARCH% within the HALCON base directory %HALCONROOT% you have chosen during the installation of HALCON.

Features

  • Support of a variety of CameraLink cameras based on the Silicon Software hardware applets.
  • Multiple frame grabber boards.
  • Synchronous and asynchronous grabbing.
  • External and software trigger.
  • Cropping of image parts.
  • Software control of the digital input and output lines.
  • Support of shaft encoders.

Limitations

  • Currently only the 'Single' hardware applets are supported.
  • grab_data and grab_data_async not supported.
  • No LUTs.

Description

Parameters for open_framegrabber():

Name 'mEnableIV' The name of the HALCON image acquisition interface.
HorizontalResolution 1 Ignored (the desired image resolution is set via the camera configuration file specified in the CameraType parameter!). Default: 1.
VerticalResolution 1 Ignored (the desired image resolution is set via the camera configuration file specified in the CameraType parameter!). Default: 1.
ImageWidth 0, width The width of the desired image part ('0' stands for the maximum image height). This value has to be equal or smaller than the maximum image height. If the value does not fit in the step width, it is rounded to next valid value. Default: 0.
ImageHeight 0, height The height of the desired image part ('0' stands for the maximum image height). This value has to be equal or smaller than the maximum image height. If the value does not fit in the step width, it is rounded to next valid value. Default: 0.
StartRow row The row coordinate of the upper left pixel of the desired image part. If the value does not fit in the step width, it is rounded to next valid value. Default: 0.
StartColumn column The column coordinate of the upper left pixel of the desired image part. If the value does not fit in the step width, it is rounded to next valid value. Default: 0.
Field --- Ignored.
BitsPerChannel --- Ignored (the desired pixel depth will be set accordingly to the parameter settings in the camera configuration file).
ColorSpace --- Ignored (the desired color space will be set accordingly to the parameter settings in the camera configuration file).
Generic --- Ignored.
ExternalTrigger 'true', 'false' If set to 'true', the trigger mode will be set to 'async_trigger', otherwise 'free_run' mode will be active. Default: 'false'.
CameraType 'mcf file' Specify the name (including the full path name) of the desired camera configuration file (mcf file). To configure a specific camera setup please use the microDisplay program which is part of microEnable IV software.
Device '0', '1', ... The number of the frame grabber board (passed as a string!). Default: '0'.
Port 0, 1 Specify the port the camera is connected to. Default: 0.
LineIn --- Ignored.

Parameters for set_framegrabber_param():

'continuous_grabbing' 'enable', 'disable' Activate or deactivate the continuous grabbing mode. If the continuous mode is enabled, the frame grabber board will grab all the time. Note that in this mode you can acquire images from line scan cameras without loosing any image data. This mode is not allowed in combination with external triggering. Default: 'disable'.
'digital_output' 0, 1, 2, 3 Specify the combination of the two digital output signals.
'exposure' 0 ... 1000000 Exposure time in µs. Default: 4000.
'exposure_signal' 'high_active', 'low_active' Polarity of the exposure signal. Default: 'low_active'.
'flash_signal' 'high_active', 'low_active' Polarity of the flash signal. Default: 'low_active'.
'frame_rate' 0.5 ... 20000.0 Number of images per second.
'grab_timeout' msec Specify the desired timeout (milliseconds passed as an integer) for aborting a pending grab. Default: 5000.
'image_height' height The height of the desired image part. Note that due to image buffer re-allocation this setting may take some time.
'image_trigger' 'enable', 'disable' Enable or disable the image trigger.
'image_trigger_input' 0, 1, 2, 3 The input source, if the image trigger is in external mode.
'image_trigger_mode' 'free_run', 'async_trigger', 'async_gated' The image trigger for line scan cameras generates an socalled Image Gate, which groups all lines to a valid frame, if it is active. Specify the desired image trigger mode: 'free run' means, that the Image Gate is valid all the time. In 'async_trigger' mode the Image Gate is started by an external trigger signal. 'async_gated' means that the Image Gate is as long active as the external trigger source is active.
In all modes the Image Gate becomes inactive after reaching an image height of N lines.
'image_trigger_signal' 'falling', 'rising' The input signal of the image trigger, in case external mode.
'image_width' width The width of the desired image part. Note that due to image buffer re-allocation this setting may take some time.
'line_downscale' 1 ... 255 If your external trigger signal is too fast, you can set the value of how often the frequency of the trigger signal has to be divided.
'line_downscale_phase' 1 ... 255 In additional to the downscale value you can set the phase position. For example, a value of 4 means to turn the phase position about 90°.
'line_exposure' 0 ... 20000 The line exposure.
'line_period' 0 ... 4369.05 The line period.
'line_trigger_delay' 0 ... 2184.517 The delay of the line trigger.
'line_trigger_input' 0, 1, 2, 3 The input source of the line trigger.
'line_trigger_mode' 'grabber_controlled', 'async_trigger', 'grabber_controlled_gated' Specify the line trigger mode: 'grabber_controlled' means that a periodical signal is created, which defines the line frequency. In 'async_trigger' mode the signal is created by an external trigger. 'grabber_controlled_gated' is similar to the 'grabber_controlled' mode, except that it is only active, if the Image Gate is active.
'line_trigger_signal' 'falling', 'rising' The polarity of the line trigger signal.
'port' 0, 1 Switch to the camera with the specified number (0 for Port A, 1 for Port B).
'shaft_encoder' 'enable', 'disable' Switch the shaft encoder on/off. By enabling it the encoder compensation is reset.
'shaft_encoder_input' 0, 1, 2, 3 Selects the input signal for source B of the shaft encoder.
'shaft_encoder_leading_source' 0, 1, 2, 3 Determines the leading signal (direction) of the shaft encoder filter.
'start_async_after_grab_async' 'enable', 'disable' By default, at the end of grab_image_async a new asynchronous grab command is automatically given to the frame grabber board. If the parameter 'start_async_after_grab_async' is set to 'disable' this new grab command is omitted. This might be useful especially for switching between several connected cameras. Default: 'enable'.
'start_column' column The column coordinate of the upper left pixel of the desired image part.
'start_row' row The row coordinate of the upper left pixel of the desired image part.
'strobe_delay' usec Strobe pulse delay in µs. Default: 0.
'trigger_input' 0, 1, 2, 3 Specify the desired channel of the trigger input signal.
'trigger_mode' 'free_run', 'grabber_controlled', 'async_trigger', 'async_software_trigger' Specify the desired trigger mode: 'free_run' means that no signals are sent to the camera. In 'grabber_controlled' mode the frame grabber sends a signal to the camera in order to control the image acquisition. In 'async_trigger' mode the image acquisition is forced by an external trigger signal, and 'async_software_trigger' means that the image acquisition is performed by software via the action parameter 'do_force_trigger'.
'trigger_signal' 'falling', 'rising' Polarity of the trigger signal. Default: 'falling'.
'volatile' 'enable', 'disable' Grayscale only. In the volatile mode the image acquisition interface buffers are used directly to store HALCON images. This is the fastest mode avoiding to copy raw images in memory. However, be aware that older images are overwritten again and again as a side-effect. Thus, you can only process one image while you grab another image. Older images are invalid! Default: 'disable'.
'do_abort_grab' --- Cancel current grab.
'do_exsync' 'enable', 'disable' Switch on/off the exsync signal to the camera.
'do_flash' 'enable', 'disable' Switch on/off the flash signal to the camera.
'do_force_trigger' --- Send a software trigger from the application to the camera. This action parameter is only applicable when the trigger mode is set to 'async_software_trigger'.

Parameters for get_framegrabber_param():

Additional parameters supported by get_framegrabber_param only. Note that all parameters supported by set_framegrabber_param except the ones with prefix 'do_' can also be accessed by get_framegrabber_param. Furthermore, corresponding to the parameters supported by set_framegrabber_param, there may exist additional read-only parameters with the following postfixes:

  • '_description': These parameters provide the tooltip of the corresponding parameter as a string.
  • '_range': These parameters provide the minimum, maximum, stepwidth, and default values for the corresponding integer or float parameter as a tuple with 4 elements, e.g., get_framegrabber_param(..,'exposure_range',..) will return the output tuple [min,max,step,default]. Optionally, this tuple can also contain additional valid string values like 'auto' or 'manual'.
  • '_values': These parameters provide the valid value list for the corresponding parameter as a tuple, e.g., get_framegrabber_param(..,'volatile_values',..) will return the output tuple ['enable','disable'].
All these postfixed parameter names are not returned when calling info_framegrabber(..,'parameters',..) and are used to enable the easy parameterization via a generic graphical user interface, particularly the HDevelop Image Acquisition Assistant.

'board_type' type Returns the actual board type.
'camera_status' status (long) Return camera status on the used port: If the return value is 1 an active camera on the specified port is found, otherwise the return value is 0.
'digital_input' digin (long) Read the current status of the digital input lines.
'revision' revision  (string) The revision number of the HALCON mEnableIV interface.

Release Notes

  • Revision 3.2 (Apr 22, 2008):
    • Added read-only parameters with postfix '_description', '_range', and '_values' to enable the easy parameterization via a generic graphical user interface.
  • Revision 3.1 (Jan 29, 2008):
    • Fixed bug in info_framegrabber('info_boards') to ensure the correct information about actually installed devices also in case of multiple boards of the same type.
  • Revision 3.0 (Jul 27, 2007):
    • First official release.