HALCON Reference Manual 10.0.2
Table of Contents / Calibration / Multi-View ClassesClassesClasses | | | Operators

calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras (Operator)

Name

calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras — Calibrate one ore more cameras.

Signature

calibrate_cameras( : : CalibDataID : Error)

Herror calibrate_cameras(const Hlong CalibDataID, double* Error)

Herror T_calibrate_cameras(const Htuple CalibDataID, Htuple* Error)

Herror calibrate_cameras(const HTuple& CalibDataID, double* Error)

double HCalibData::CalibrateCameras() const

void HOperatorSetX.CalibrateCameras(
[in] VARIANT CalibDataID, [out] VARIANT* Error)

double HCalibDataX.CalibrateCameras()

static void HOperatorSet.CalibrateCameras(HTuple calibDataID, out HTuple error)

double HCalibData.CalibrateCameras()

Description

The operator calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras calibrates a setup of one or more cameras based on the calibration data model CalibDataIDCalibDataIDCalibDataIDCalibDataIDcalibDataID. The used calibration algorithm depends on the calibration setup type specified during the creation of the data model, see create_calib_datacreate_calib_datacreate_calib_dataCreateCalibDataCreateCalibData. Currently, only the type 'calibration_object'"calibration_object""calibration_object""calibration_object""calibration_object" is supported.

In this setup, one or more cameras are calibrated, i.e. their internal parameters (e.g., their focal length) and their poses relative to the coordinate system of a so-called reference camera are calculated (see the paragraph Üsed 3D camera model" for details of the used 3D point projection model). For this, one or more calibration objects (e.g., the HALCON calibration plate), are placed in front of the cameras. These objects have precisely known metric properties. The calibration objects are observed by the cameras in different calibration object poses, i.e., the cameras acquire an image of the calibration objects for each of their poses and extract metric information. Note that only cameras of the same type can be calibrated in a single setup. Furthermore, area-scan cameras with telecentric lens and line-scan cameras can be calibrated only one at a time.

The camera calibration corresponds to an optimization of the internal parameters and the poses of the cameras and of the calibration objects' poses such that the backprojection of calibration object feature points into the modelled cameras fits the actual observed projections as well as possible. Note that the optimization needs an initial estimate for the internal camera parameters. In contrast, the initial poses of both cameras and calibration objects are not needed and remain at first undefined. Instead, for each observation a rough estimate of the pose of the calibration object relative to the observing camera is required. From these poses, the camera and calibration object poses are initialized in the first step of the camera calibration calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras (see the section "Performing camera calibration" for more details).

Preparing the calibration input data

Before calling calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras, you must create and fill the calibration data model with the following steps:

  1. Create a calibration data model with the operator create_calib_datacreate_calib_datacreate_calib_dataCreateCalibDataCreateCalibData, specifying the number of cameras in the setup and the number of used calibration objects.

  2. Specify camera type and the initial internal camera parameters for all cameras with the operator set_calib_data_cam_paramset_calib_data_cam_paramset_calib_data_cam_paramSetCalibDataCamParamSetCalibDataCamParam.

  3. Specify the description of all calibration objects with the operator set_calib_data_calib_objectset_calib_data_calib_objectset_calib_data_calib_objectSetCalibDataCalibObjectSetCalibDataCalibObject.

  4. Collect observation data with the operator set_calib_data_observ_pointsset_calib_data_observ_pointsset_calib_data_observ_pointsSetCalibDataObservPointsSetCalibDataObservPoints, i.e., the image coordinates of the extracted calibration object markers and a roughly estimated pose of the calibration object relative to observing camera.

  5. Configure the calibration process, e.g., specify the reference camera or exclude certain internal or external camera parameters from the optimization. With the operator set_calib_dataset_calib_dataset_calib_dataSetCalibDataSetCalibData, you can specify parameters for the complete setup, or configure parameters of individual cameras or calibration objects poses in the setup.

    For example, if a certain camera parameter, for example the image sensor cell size, is known and only the rest of the parameters need to be calibrated, you call

         set_calib_data(CalibDataID,'camera','general','excluded_params',['sx','sy']).
      

Performing the actual camera calibration

Depending on the camera type being calibrated in the setup, calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras performs the calibration in two different ways.

For projective area-scan cameras, 'area_scan_division'"area_scan_division""area_scan_division""area_scan_division""area_scan_division" and 'area_scan_polynomial'"area_scan_polynomial""area_scan_polynomial""area_scan_polynomial""area_scan_polynomial", the calibration is performed in three steps. First, the algorithm tries to build a chain of observation poses, which connects all cameras and calibration object poses to the reference camera, e.g.:

        obs[0,0,0]            obs[1,0,0]     obs[1,0,1]           obs[2,0,1]      obs[2,..]
  camera[0] -> calib_obj_pose[0,0] <- camera[1] -> calib_obj_pose[0,1] <- camera[2] -> ...
(ref_camera)

If there is a camera that cannot be reached (i.e. it is not observing any calibration object pose that can be connected in the chain), the calibration process is terminated with an error. Otherwise, the algorithm initializes all calibration items' poses by going down this chain. In the second step, calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras performs the actual optimization for all optimization parameters, which where not explicitly excluded from calibration. In the last step calibrate_camerascalibrate_camerascalibrate_camerasCalibrateCamerasCalibrateCameras computes the standard deviations and the covariances of the calibrated camera internal parameters.

For cameras of type 'area_scan_telecentric_division'"area_scan_telecentric_division""area_scan_telecentric_division""area_scan_telecentric_division""area_scan_telecentric_division", 'area_scan_telecentric_polynomial'"area_scan_telecentric_polynomial""area_scan_telecentric_polynomial""area_scan_telecentric_polynomial""area_scan_telecentric_polynomial" or 'line_scan'"line_scan""line_scan""line_scan""line_scan" the operator internally calls camera_calibrationcamera_calibrationcamera_calibrationCameraCalibrationCameraCalibration. Therefore, some of the restrictions of camera_calibrationcamera_calibrationcamera_calibrationCameraCalibrationCameraCalibration are inherited as well: next to the already mentioned restrictions of only one camera and only one calibration object per setup, there is a further restriction that all observations need to contain the projection coordinates of all calibration object markers. Furthermore, calibration with these camera types does not deliver information about standard deviations and covariances for the estimated optimization parameters.

Checking the success of the calibration

After a successful calibration, the average backprojection error of the optimization is returned in ErrorErrorErrorErrorerror (in pixel) and gives general indication whether the optimization was successful. An ErrorErrorErrorErrorerror in the order of 0.5-1.5 pixel (the typical detection error by extraction of the coordinates of the projected calibration markers) is an indication that the optimization fits the observation data well. For further analysis of the calibration quality, refer to standard deviations and covariances of the estimated parameters (currently for projective area-scan cameras only, see get_calib_dataget_calib_dataget_calib_dataGetCalibDataGetCalibData).

Getting the calibration results

The results of the calibration, i.e., internal camera parameters, camera poses, calibration objects poses etc., can be queried with get_calib_dataget_calib_dataget_calib_dataGetCalibDataGetCalibData.

Used 3D camera model

In general, camera calibration means the exact determination of the parameters that model the (optical) projection of any 3D world point P(w) into a (sub-)pixel [r,c] in the image. The projection consists of multiple steps: First, the point p(w) is transformed from world into camera coordinates (points as homogeneous vectors, compare affine_trans_point_3daffine_trans_point_3daffine_trans_point_3dAffineTransPoint3dAffineTransPoint3d):

  /      \     / x \     /        \   /      \
  | p(c) |  =  | y |  =  |  R   t | * | p(w) |
  |      |     | z |     |        |   |      |
  \  1   /     \ 1 /     \ 0 0  1 /   \  1   /

Then, the point is projected into the image plane, i.e., onto the sensor chip.

For the modeling of this projection process that is determined by the used combination of camera, lens, and frame grabber, HALCON provides the following three 3D camera models:

For area-scan cameras, the projection of the point p(c) that is given in camera coordinates into a (sub-)pixel [r,c] in the image consists of the following steps: First, the point is projected into the image plane, i.e., onto the sensor chip. If the underlying camera model is an area-scan pinhole camera, i.e., if the focal length is greater than 0, the projection is described by the following equations:

           / x \
    p(c) = | y |
           \ z /

    u = Focus * x / z
    v = Focus * y / z

In contrast, if the focal length is 0, the camera model of an area-scan telecentric camera is used, i.e., it is assumed that the optics of the lens of the camera performs a parallel projection. In this case, the corresponding equations are:

           / x \
    p(c) = | y |
           \ z /

    u = x
    v = y

For both types of area-scan cameras, the lens distortions can be modelled either by the division model or by the polynomial model. The division model uses one parameter (Kappa) to model the radial distortions.

The following equations transform the distorted image plane coordinates into undistorted image plane coordinates if the division model is used:

   u = u' / (1+Kappa*(u'^2+v'^2)
   v = v' / (1+Kappa*(u'^2+v'^2)

These equations can be inverted analytically, which leads to the following equations that transform undistorted coordinates into distorted coordinates if the division model is used:

   u' = (2*u) / (1+sqrt(1-4*Kappa*(u^2+v^2)))
   v' = (2*v) / (1+sqrt(1-4*Kappa*(u^2+v^2)))

The polynomial model uses three parameters (K1, K2, K3) to model the radial distortions, and two parameters (P1, P2) to model the decentering distortions. The following equations transform the distorted image plane coordinates into undistorted image plane coordinates if the polynomial model is used:

   u = u' + u'*(K1*r^2 + K2*r^4 + K3*r^6) +
            2*P1*u'*v' + P2*(r^2 + 2*u'^2)

   v = v' + v'*(K1*r^2 + K2*r^4 + K3*r^6) +
            P1*(r^2 + 2*v'^2) + 2*P2*u'*v'

   r = sqrt(u'^2+v'^2)

These equations cannot be inverted analytically. Therefore, distorted image plane coordinates must be calculated from undistorted image plane coordinates numerically.

Finally, the point is transformed from the image plane coordinate system into the image coordinate system, i.e., the pixel coordinate system:

    c = u' / Sx + Cx
    r = v' / Sy + Cy

For line-scan cameras, also the relative motion between the camera and the object must be modeled. In HALCON, the following assumptions for this motion are made:

  1. the camera moves with constant velocity along a straight line

  2. the orientation of the camera is constant

  3. the motion is equal for all images

The motion is described by the motion vector V = (Vx,Vy,Vz)' that must be given in [meter/scanline] in the camera coordinate system. The motion vector describes the motion of the camera, assuming a fixed object. In fact, this is equivalent to the assumption of a fixed camera with the object travelling along -V.

The camera coordinate system of line scan cameras is defined as follows: The origin of the coordinate system is the center of projection. The z-axis is identical to the optical axis and directed so that the visible points have positive z coordinates. The y-axis is perpendicular to the sensor line and to the z-axis. It is directed so that the motion vector has a positive y-component. The x-axis is perpendicular to the y- and z-axis, so that the x-, y-, and z-axis form a right-handed coordinate system.

As the camera moves over the object during the image acquisition, also the camera coordinate system moves relatively to the object, i.e., each image line has been imaged from a different position. This means, there would be an individual pose for each image line. To make things easier, in HALCON, all transformations from world coordinates into camera coordinates and vice versa are based on the pose of the first image line only. The motion V is taken into account during the projection of the point p(c) into the image. Consequently, only the pose of the first image line is returned by the operator find_marks_and_posefind_marks_and_posefind_marks_and_poseFindMarksAndPoseFindMarksAndPose (and stored in the calibration results).

For line-scan pinhole cameras, the projection of the point p(c) that is given in the camera coordinate system into a (sub-)pixel [r,c] in the image is defined as follows:

Assuming

           / x \
    p(c) = | y |,
           \ z /

the following set of equations must be solved for m, u', and t:

    m * D * u' = x - t * Vx
   -m * D * pv = y - t * Vy
    m * Focus  = z - t * Vz

with

                   1
    D  = -----------------------
         1 + Kappa*(u'*u' + pv*pv)

    pv = Sy*Cy

This already includes the compensation for radial distortions. Note that for line scan cameras, only the division model for radial distortions can be used.

Finally, the point is transformed into the image coordinate system, i.e., the pixel coordinate system:

    c = u' / Sx + Cx
    r = t

Attention

A camera calibration data model CalibDataID cannot be shared between two or more user's threads. Different camera calibration data models can be used independently and safely in different threads.

Parallelization

Parameters

CalibDataIDCalibDataIDCalibDataIDCalibDataIDcalibDataID (input_control)  calib_data HCalibData, HTupleHCalibData, HTupleHCalibDataX, VARIANTHtuple (integer) (IntPtr) (Hlong) (Hlong) (Hlong)

Handle of a calibration data model.

ErrorErrorErrorErrorerror (output_control)  number HTupleHTupleVARIANTHtuple (real) (double) (double) (double) (double)

Average backprojection error of the optimization.

Possible Predecessors

create_calib_datacreate_calib_datacreate_calib_dataCreateCalibDataCreateCalibData, set_calib_data_cam_paramset_calib_data_cam_paramset_calib_data_cam_paramSetCalibDataCamParamSetCalibDataCamParam, set_calib_data_calib_objectset_calib_data_calib_objectset_calib_data_calib_objectSetCalibDataCalibObjectSetCalibDataCalibObject, set_calib_data_observ_pointsset_calib_data_observ_pointsset_calib_data_observ_pointsSetCalibDataObservPointsSetCalibDataObservPoints, set_calib_dataset_calib_dataset_calib_dataSetCalibDataSetCalibData

Possible Successors

get_calib_dataget_calib_dataget_calib_dataGetCalibDataGetCalibData

Module

Calibration