ClassesClassesClassesClasses | | | | Operators

get_metrology_object_num_instancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesGetMetrologyObjectNumInstances (Operator)

Name

get_metrology_object_num_instancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesGetMetrologyObjectNumInstances — Get the number of instances of the metrology objects of a metrology model.

Signature

get_metrology_object_num_instances( : : MetrologyHandle, Index : NumInstances)

Herror get_metrology_object_num_instances(const Hlong MetrologyHandle, const Hlong Index, double* NumInstances)

Herror T_get_metrology_object_num_instances(const Htuple MetrologyHandle, const Htuple Index, Htuple* NumInstances)

Herror get_metrology_object_num_instances(const HTuple& MetrologyHandle, const HTuple& Index, double* NumInstances)

Herror get_metrology_object_num_instances(const HTuple& MetrologyHandle, const HTuple& Index, HTuple* NumInstances)

HTuple HMetrologyModel::GetMetrologyObjectNumInstances(const HTuple& Index) const

void GetMetrologyObjectNumInstances(const HTuple& MetrologyHandle, const HTuple& Index, HTuple* NumInstances)

HTuple HMetrologyModel::GetMetrologyObjectNumInstances(const HTuple& Index) const

double HMetrologyModel::GetMetrologyObjectNumInstances(Hlong Index) const

void HOperatorSetX.GetMetrologyObjectNumInstances(
[in] VARIANT MetrologyHandle, [in] VARIANT Index, [out] VARIANT* NumInstances)

VARIANT HMetrologyModelX.GetMetrologyObjectNumInstances([in] VARIANT Index)

static void HOperatorSet.GetMetrologyObjectNumInstances(HTuple metrologyHandle, HTuple index, out HTuple numInstances)

HTuple HMetrologyModel.GetMetrologyObjectNumInstances(HTuple index)

double HMetrologyModel.GetMetrologyObjectNumInstances(int index)

Description

get_metrology_object_num_instancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesGetMetrologyObjectNumInstances allows to access the number of instances (results) of measurements applied by apply_metrology_modelapply_metrology_modelApplyMetrologyModelapply_metrology_modelApplyMetrologyModelApplyMetrologyModel for the metrology objects. Note that by default, the maximum number of instances of each metrology object is set to 1. Thus, by default, the result of get_metrology_object_num_instancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesGetMetrologyObjectNumInstances will typically be 1 as well. To allow more instances, before applying the measurement with apply_metrology_modelapply_metrology_modelApplyMetrologyModelapply_metrology_modelApplyMetrologyModelApplyMetrologyModel you have to explicitly set the parameter 'num_instances'"num_instances""num_instances""num_instances""num_instances""num_instances" to a higher value or to 'all'"all""all""all""all""all" using set_metrology_object_paramset_metrology_object_paramSetMetrologyObjectParamset_metrology_object_paramSetMetrologyObjectParamSetMetrologyObjectParam.

For an explanation of the concept of 2D metrology see the introduction of chapter 2D Metrology.

The metrology model is defined by the handle MetrologyHandleMetrologyHandleMetrologyHandleMetrologyHandleMetrologyHandlemetrologyHandle. The parameter IndexIndexIndexIndexIndexindex specifies for which metrology object the instances are queried. For IndexIndexIndexIndexIndexindex set to 'all'"all""all""all""all""all", the number of instances of all metrology objects are returned. The number of instances is returned in NumInstancesNumInstancesNumInstancesNumInstancesNumInstancesnumInstances for each metrology object that was passed in IndexIndexIndexIndexIndexindex.

Parallelization

Parameters

MetrologyHandleMetrologyHandleMetrologyHandleMetrologyHandleMetrologyHandlemetrologyHandle (input_control)  metrology_model HMetrologyModel, HTupleHTupleHMetrologyModel, HTupleHMetrologyModelX, VARIANTHtuple (integer) (IntPtr) (Hlong) (Hlong) (Hlong) (Hlong)

Handle of the metrology model.

IndexIndexIndexIndexIndexindex (input_control)  integer(-array) HTupleHTupleHTupleVARIANTHtuple (integer / string) (int / long / string) (Hlong / HString) (Hlong / char*) (Hlong / BSTR) (Hlong / char*)

Index of the metrology objects.

Default value: 0

Suggested values: 'all'"all""all""all""all""all", 0, 1, 2

NumInstancesNumInstancesNumInstancesNumInstancesNumInstancesnumInstances (output_control)  integer(-array) HTupleHTupleHTupleVARIANTHtuple (real / integer) (double / int / long) (double / Hlong) (double / Hlong) (double / Hlong) (double / Hlong)

Number of Instances of the metrology objects.

Result

If the parameters are valid, the operator get_metrology_object_num_instancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesget_metrology_object_num_instancesGetMetrologyObjectNumInstancesGetMetrologyObjectNumInstances returns the value 2 (H_MSG_TRUE). If necessary, an exception is raised.

Possible Predecessors

apply_metrology_modelapply_metrology_modelApplyMetrologyModelapply_metrology_modelApplyMetrologyModelApplyMetrologyModel

Possible Successors

clear_metrology_modelclear_metrology_modelClearMetrologyModelclear_metrology_modelClearMetrologyModelClearMetrologyModel

See also

get_metrology_object_indicesget_metrology_object_indicesGetMetrologyObjectIndicesget_metrology_object_indicesGetMetrologyObjectIndicesGetMetrologyObjectIndices

Module

2D Metrology


ClassesClassesClassesClasses | | | | Operators