HALCON 8.0 Image Acquisition Interface for SICK IVP Ranger D/E 3D Cameras
This page provides the documentation of the HALCON RangerE
image acquisition interface for
SICK IVP Ranger D and Ranger E cameras.
Registered
customers can download the
latest
revision of this interface from the
MVTec WWW server.
Revision: 3.2
System Requirements
-
Intel compatible PC with Windows XP.
-
Intel PRO/1000 network interface card.
-
Successfully installed eBUS high performance driver.
-
Successfully installed SICK IVP Ranger Studio version 3.3
(the interface was built with icon_API version 3.3.1.1). Please
make sure that the the icon_c_33.dll is available
via the %PATH% environment variable.
Note that for using the HALCON RangerE interface
you need a valid .prm file (e.g. Ranger E55 Default.prm)
for your specific camera configuration, which can be
created using Ranger Studio.
-
HALCON image acquisition interface hAcqRangerE.dll or
parhAcqRangerE.dll, respectively. If you have installed
the interface properly, both DLLs should reside in
bin\%HALCONARCH% within the HALCON base directory
%HALCONROOT% you have chosen during the installation of HALCON.
Features
-
Synchronous and asynchronous grabbing.
-
Image or measurement configuration available.
-
Access to multiple measurement components via multi-channel images.
-
Software control of all camera parameters.
Limitations
-
grab_data and grab_data_async not supported.
-
No LUTs.
Description
Parameters for
open_framegrabber():
|
Name
|
|
'RangerE'
|
|
The name of the HALCON image acquisition interface.
|
|
HorizontalResolution
|
---
|
Ignored.
|
|
VerticalResolution
|
---
|
Ignored.
|
|
ImageWidth
|
0, 256 ... 1536
|
The width of the desired image part. Please note that the image
width must be divisible by 8. If set to 0 the value in the prm-file
(or the current setting of the camera) is used.
Default: 0.
|
|
ImageHeight
|
0, height
|
The height of the desired image part (in image mode) or the number
of scans (in measurement mode). If set to 0 the value in the
prm-file (or the current setting of the camera) is used.
Default: 0.
|
|
StartRow
|
---
|
Ignored.
|
|
StartColumn
|
0, 1 ... 1280
|
The column coordinate of the upper left pixel within the desired
image part. Note that the sum of StartColumn
and ImageWidth must not exceed 1536. If set to 0 the value in the
prm-file (or the current setting of the camera) is used.
|
|
Field
|
---
|
Ignored.
|
|
BitsPerChannel
|
---
|
Ignored (the number of bits per channel is determined automatically
by reading the parameter file).
|
|
ColorSpace
|
'image', 'measurement'
|
The desired camera configuration. If set to 'image', every call
of grab_image and grab_image_async will result
in a gray value image. If set to 'measurement', a multi-channel
image with the actual 3D measurements will be returned.
Default: 'measurement'.
|
|
Generic
|
buffer size, -1
|
Buffer size in MB. Default: 50.
|
|
ExternalTrigger
|
'true', 'false'
|
Activate/deactivate external triggering. If activated,
pulse triggering is used.
|
|
CameraType
|
prm-file, 'default'
|
Name of the camera parameter file. In case of 'default', the
current camera settings are used.
Default: 'default'.
|
|
Device
|
ip_address
|
IP address of the camera.
|
|
Port
|
---
|
Ignored.
|
|
LineIn
|
---
|
Ignored.
|
|
Parameters for
set_framegrabber_param():
Note that most of the following parameters (and also the valid
parameter values!) depend on the capabilities of the used camera.
Furthermore, the default values may depend on the current camera
settings.
|
'active_channel'
|
|
value
|
|
Sets the number of the active channel if measurement
configuration is chosen.
|
|
'configuration'
|
'image', 'measurement'
|
Sets the configuration of the camera. If set to 'image', every call
of grab_image and grab_image_async will result
in a gray value image. If set to 'measurement', a multi-channel
image with the actual 3D measurements will be returned.
Default: 'measurement'.
|
|
'continuous_grabbing'
|
'enable', 'disable'
|
If 'continuous_grabbing' is enabled, data is continuously acquired
by the camera. Otherwise data is only acquired when calling
grab_image or grab_image_async.
|
|
'do_save_parameters'
|
prm-file
|
Save the parameter settings to the specified filename.
|
|
'grab_timeout'
|
value
|
Specify the desired timeout (milliseconds passed as an integer) for
aborting a pending grab. Default: 5000.
|
|
'module_name'
|
name
|
The name of the parameter to be changed, e.g., 'number of rows'.
|
|
'module_path'
|
path
|
The path to a component in the XML structure.
|
|
'module_value'
|
value
|
The new value for the parameter specified by the parameters
'module_name' and 'module_path'.
|
|
'trigger_mode'
|
'0', '2'
|
If 'trigger_mode' is set to '0' the camera is free running;
if set to '2' pulse triggering is activated.
|
Parameters for
get_framegrabber_param():
Additional parameters supported by get_framegrabber_param only.
Note that all parameters supported by set_framegrabber_param
except the ones with prefix 'do_' can also be accessed by
get_framegrabber_param. Furthermore, corresponding to the
parameters supported by set_framegrabber_param, there may
exist additional read-only parameters with the following postfixes:
-
'_description': These parameters provide the tooltip of the
corresponding parameter as a string.
-
'_range': These parameters provide the minimum, maximum,
stepwidth, and default values for the corresponding integer or float
parameter as a tuple with 4 elements, e.g.,
get_framegrabber_param(..,'exposure_range',..) will return
the output tuple [min,max,step,default]. Optionally,
this tuple can also contain additional valid string values like
'auto' or 'manual'.
-
'_values': These parameters provide the valid value list for
the corresponding parameter as a tuple, e.g.,
get_framegrabber_param(..,'volatile_values',..) will return
the output tuple ['enable','disable'].
All these postfixed parameter names are not returned when calling
info_framegrabber(..,'parameters',..) and are used
to enable the easy parameterization via a generic graphical user
interface, particularly the HDevelop Image Acquisition Assistant.
|
'channel_names'
|
|
channel_names (string)
|
|
The component names of the accessible channels are returned
as a tuple of strings.
|
|
'image_available'
|
image_available (int)
|
Returns the status of the last asynchronous grab command.
The value 1 means that the image is already acquired and
thus can be fetched by grab_image_async without delay.
|
|
'revision'
|
revision (string)
|
The revision number of the HALCON interface.
|
Release Notes
-
Revision 3.2 (Apr 23, 2008):
-
Bugfix in info_framegrabber(...,'device',...) to
prevent accessing uninitialized memory.
-
Added read-only parameters with postfix '_description', '_range',
and '_values' to enable the easy parameterization via a generic
graphical user interface.
-
Revision 3.1 (Feb 27, 2008):
-
Adapted to icon_API version 3.3.
-
In open_framegrabber, the trigger was not disabled when
ExternalTrigger was set to 'false'. This bug has been
fixed.
-
In case of grab timeouts, empty images were delivered. This bug
has been fixed.
-
Improved image buffer handling.
-
Revision 3.0 (Oct 16, 2007):
|